  • Max Pressure Differential (PSI): 20 psi

  • Max Water Temp (°F): 250°F

  • Operating Range (psi): 0.5 to 2.9 psi

  • Max Ambient Temp (°F): 122°F

- +
  • Max Pressure Differential (PSI): 20 psi

  • Max Water Temp (°F): 250°F

  • Operating Range (psi): 0.5 to 2.9 psi

  • Max Ambient Temp (°F): 122°F

Product details

Macon Controls MAC-EVO-28 EVO-Series Direct Mount Thermostatic Operator (2013401028)

The Macon EVO thermostatic operator will help you balance your heating system. The EVO operator has one of the most accurate sensors available for radiator temperature control. The problems of overheating, under-heating and wide temperature swings can now be minimized.

The EVO thermostatic operator by Macon Controls conserves energy by regulating temperature. Fuel costs can be reduced up to 30%!

The EVO is a self-acting, adjustable, non-electric thermostatic operator. It has adjustable max./min. temperature, selected temperature locking feature and can be shutoff completely if required. The symbol * protects against frost damage. Each EVO thermostatic operator is individually calibrated and conforms to ASHRAE standardization rules for temperature regulation. The EVO’s smooth shape and narrow air gaps gives a nice operation and makes it easy to keep clean. They can be mounted on all Macon NT series valves. Millions are in use throughout the world.

Features

    Maximum/Minimum Setting:
  • Turn the wheel to maximum or minimum.

  • Push the mark in with limit tool (located opposite the dial setting window) and press in the wheel handle 1-2 mm until it stops.

  • Remove the limit tool and press in the wheel handle until it stops.

  • Minimum Setting:
  • Turn the wheel to minimum and a blue mark will occur in the indicating window (located opposite the dial setting window).

  • Push the mark in while turning the wheel to desired temperature according to below chart.

  • When reached desired temperature let go of the mark and the minimum temperature limit DATA is set.

  • Set the required temperature according to the chart above.

  • Pull the wheel handle out and the maximum or minimum temperature is set.

Specification Sheet

Basic Information
MPN ? Manufacturer Part Number MAC-EVO-28
Dimensions and Measurements
Weight ? Weight 0.99
Characteristics and Features
Valve PSI 20 PSI